Facts About Dp50rb Revealed
Facts About Dp50rb Revealed
Blog Article
.. Site 161 The indicator within the printer Errors happen once the adapter turns orange, plus the printing printer adapter runs. Disconnect and connect the fails. electricity adapter, ability to the printer adapter once again, and confirm if the printing is usual right after one moment. Website page 163: Electrical Protection Inspection
Dengan obshape baru yang cerdas dan desain layar penuh, mobilitas yang ditingkatkan, dan pengoperasian yang lebih nyaman, sistem yang andal dan terjangkau ini akan meningkatkan praktik umum dan sangat cocok untuk berbagai kebutuhan klinis.
Cookie penting untuk memfungsikan situs dengan semestinya. Untuk meningkatkan pengalaman Anda, kami menggunakan cookie untuk mengingat depth login Anda dan menyediakan login aman, mengumpulkan statistik untuk mengoptimalkan fungsionalitas situs, dan menyediakan konten yang disesuaikan dengan minat Anda.
Any time you cease the scanning as well as the image seize, you must electricity from the technique and disconnect the system with the AC power supply, then pull out AC energy cables. Website page 109: Battery Connecting Board
Permits use of various scanned angles to kind a single picture, leading to Increased contrast resolution and enhanced visualization
Webpage 145 Clean up user interface Instruments: dry delicate cloth, moderate soapy water Strategy: Use dry smooth fabric to scrub the area in the program. In case the procedure is dirty, moisten the comfortable cloth with gentle soapy drinking water and wipe off any stains. Use dry delicate fabric to eliminate any humidity and allow all tricky surfaces to wholly air-dry. Website page 146: Clean up The Peripherals
Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi detail mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.
The DP-50 Pro is an revolutionary, large-functionality Ultrasound Process engineered to help you have the insights you would like. The Procedure’s impressive engine and higher-velocity processing give fantastic picture top quality and an entire data administration Option.
Perform: On the back again-conclusion of the primary board, a special observe IC is applied to observe sign voltages and clock battery electric power which are delivered to the main board by the principle device box energy supply module.
The chapter supplies the strategy to confirm key perform and performance of solution. That is only utilized for reference, not preventive execution. Functionality checking and tests of this part shall be completed by Mindray services engineers as well as person with each other. Page 66: Typical Examination
NOTE: About the watch, the brightness adjustment will come before distinction. After readjusting the check’s contrast and brightness, modify all preset and peripheral settings.
Notice: Prior to inserting the connector into your probe port, inspect the connector pin. In case the pin is bent, usually do not utilize the probe right up until it has been inspected / repaired / replaced. Setting up Peripherals To the models on the supported peripherals, make sure you check with “2.
Just after replacing the CPU module, essential file must be produced Again according to the new MAC tackle and penned into HDD in the device. Or else, the configuration functionality from the merchandise will be misplaced. Immediately after removing the CPU module, Get rid of panhead screws with washers (12 M3X6) mounted on the most crucial device box, you can take from the board. Web site 118 Determine eight-29 Disassemble the User interface Assembly (1) Maintain the upper edge of control panel assembly, and open up up the control panel. Determine eight-thirty Disassemble the Control Panel Assembly (2) Right after eliminating just one countersunk head self-tapping screw PT3X10 fastened to the user interface and just take out the plug Dp50rb login with the keyboard and the leading device connecting cables, you might take away the control panel assembly.
General performance Test five.5.one Check Process Resolution Detection depth Geometric Posture Accuracy Blackout place take a look at Record the Test pictures five.5.two Take a look at Content material The image utilised Here's just for reference, stick to the graphic influence in the true Take note: scenario. Needs: Display screen: set the contrast and brightness in the medical application benefit (or the default position) Operation ecosystem: dark room, simulating the scientific application natural environment. Page seventy six In issue the transverse resolution tests targets are horizontally exhibited, file the minimum distance of two targets which might be Evidently recognized. Repeat the operation previously mentioned for that transverse resolution screening targets at other depths. As shown in determine beneath. Axial resolution ... Web site seventy seven When using the convex probe, continue to keep the transverse resolution screening targets to NOTE: be shown near the midline. When utilizing a linear probe with steer operate, never turn on the steer function when complete the transverse resolution check. Zoom during the area where the targets Situated if needed. The diameter with the concentrate on issue at a certain depth is equivalent to your transverse resolution for the depth. Page 78 5.
Mindray respects your privateness. We use cookies for many different reasons, for example Site functionality, bettering your working experience of our Web site, making integration with social networking and helping focus on our promoting.
5.two.3 Geometric positioning precision Longitudinal geometric positioning precision Check Move: Do adjustments as the best way in tests the most depth. History the gap by 20mm Each individual section within the longitudinal targets line utilizing the measurement caliper; Choose the worth with the greatest error (to 20mm), compute the accuracy utilizing the formulation under The measurement caliper ought to be positioned on the upper fringe of the target, Observe:... Page 79 Transverse geometric positioning accuracy Examination Move: Go over the scan surface of your phantom with drinking water or couple gel, Carefully Get in touch with the probe Together with the scan surface Regulate the depth, producing the transverse targets to get displayed during the picture. Adjust the main target position to generally be posited beside the transverse targets (the regular will not be clear) Change parameters like get, TGC, generating Every single transverse targets to get clearly exhibited. Webpage eighty five.5.two.four Blackout Region Test Action: Protect the scan surface with the phantom with drinking water or couple gel, gently Make contact with the probe With all the scan surface area Modify the depth in a decreased value, and set the main target at the nearest place to the scan surface. Lessen the worth of parameters like AP, Achieve until finally the history noise just is usually observed. Page 81: Program Upgrade And Maintenance